skip to main content
Ngôn ngữ:
Giới hạn tìm kiếm: Giới hạn tìm kiếm: Dạng tài nguyên Hiển thị kết quả với: Hiển thị kết quả với: Chỉ mục

The effect of dentine surface preparation and reduced application time of adhesive on bonding strength

Saikaew, Pipop ; Chowdhury, A.F.M. Almas ; Fukuyama, Mai ; Kakuda, Shinichi ; Carvalho, Ricardo M. ; Sano, Hidehiko

Journal of Dentistry, April 2016, Vol.47, pp.63-70 [Tạp chí có phản biện]

ISSN: 0300-5712 ; DOI: 10.1016/j.jdent.2016.02.001

Toàn văn sẵn có

Trích dẫn Trích dẫn bởi
  • Nhan đề:
    The effect of dentine surface preparation and reduced application time of adhesive on bonding strength
  • Tác giả: Saikaew, Pipop ; Chowdhury, A.F.M. Almas ; Fukuyama, Mai ; Kakuda, Shinichi ; Carvalho, Ricardo M. ; Sano, Hidehiko
  • Chủ đề: Universal Adhesives ; Microtensile Bond Strength ; Bonding Application Time ; Surface Preparation ; SEM
  • Là 1 phần của: Journal of Dentistry, April 2016, Vol.47, pp.63-70
  • Mô tả: ObjectiveThis study evaluated the effects of surface preparation and the application time of adhesives on the resin–dentine bond strengths with universal adhesives. MethodsSixty molars were cut to exposed mid-coronal dentine and divided into 12 groups (n=5) based on three factors; (1) adhesive: G-Premio Bond (GP, GC Corp., Tokyo, Japan), Clearfil Universal Bond (CU, Kuraray Noritake Dental Inc., Okayama, Japan) and Scotchbond Universal Adhesive (SB, 3M ESPE, St. Paul, MN, USA); (2) smear layer preparation: SiC paper ground dentine or bur-cut dentine; (3) application time: shortened time or as manufacturer’s instruction. Fifteen resin–dentine sticks per group were processed for microtensile bond strength test (μTBS) according to non-trimming technique (1mm2) after storage in distilled water (37°C) for 24h. Data were analyzed by three-way ANOVA and Dunnett T3 tests (α=0.05). Fractured surfaces were observed under scanning electron microscope (SEM). Another 12 teeth were prepared and cut into slices for SEM examination of bonded interfaces. ResultsμTBS were higher when bonded to SiC-ground dentine according to manufacturer’s instruction. Bonding to bur-cut dentine resulted in significantly lower μTBS (p<0.000). Shortening the application time resulted in significantly lower bond strength for CU on SiC and GP on bur-cut dentine. SEM of fractured surfaces revealed areas with a large amount of porosities at the adhesive resin interface. This was more pronounced when adhesives were bonded with a reduced application time and on bur cut dentine. Clinical significanceThe performance of universal adhesives can be compromised on bur cut dentine and when applied with a reduced application time.
  • Ngôn ngữ: English
  • Số nhận dạng: ISSN: 0300-5712 ; DOI: 10.1016/j.jdent.2016.02.001

Đang tìm Cơ sở dữ liệu bên ngoài...