skip to main content
Ngôn ngữ:
Giới hạn tìm kiếm: Giới hạn tìm kiếm: Dạng tài nguyên Hiển thị kết quả với: Hiển thị kết quả với: Chỉ mục

Statistical evaluation of a novel SSVEP-BCI stimulation setup based on depth-of-field

Cotrina, Anibal ; Benevides, Alessandro Botti ; Castillo-Garcia, Javier ; Ferreira, Andre ; Bastos Filho, Teodiano Freire

Research on Biomedical Engineering, 01 October 2015, Vol.31(4), pp.295-306 [Tạp chí có phản biện]

ISSN: 2446-4740 ; E-ISSN: 2446-4740 ; DOI: 10.1590/2446-4740.0752

Truy cập trực tuyến

Phiên bản sẵn có
Trích dẫn Trích dẫn bởi
  • Nhan đề:
    Statistical evaluation of a novel SSVEP-BCI stimulation setup based on depth-of-field
  • Tác giả: Cotrina, Anibal ; Benevides, Alessandro Botti ; Castillo-Garcia, Javier ; Ferreira, Andre ; Bastos Filho, Teodiano Freire
  • Chủ đề: Engineering, Biomedical ; Brain-Computer Interface ; Steady-State Visual Evoked Potential ; Depth-of-Field ; Objective Response Detection ; Statistical F-Test ; Engineering
  • Là 1 phần của: Research on Biomedical Engineering, 01 October 2015, Vol.31(4), pp.295-306
  • Mô tả: Abstract Introduction The main drawback of a Brain-computer Interface based on Steady-State Visual Evoked Potential (SSVEP-BCI) that detects the emergence of visual evoked potentials (VEP) in reaction to flickering stimuli is its muscular dependence due to users must redirect their gaze to put the target stimulus in their field of view. In this work, a novel setup is evaluated in which two stimuli are placed together in the center of users' field of view, but with dissimilar distances from them, so that the target selection is performed by focus shifting instead of head, neck and/or eyeball movements. Methods A model of VEP generation for the novel setup was developed. The Spectral F-test based on Bartett periodogram was used to evaluate the null hypothesis of absence of effects of the non-focused stimulus (NFS) within the VEP elicited by the focused stimulus (FS). To reinforce that there is not statistical evidence to support the presence of NFS effects, the PSDA detection method was employed to find the frequency of FS. Electroencephalographic signals of nine subjects were recorded. Results Approximately in 80% of the tests, the null hypothesis with 5% level of significance was non-rejected at the fundamental frequency of NFS. The average of the accuracy rate attained with PSDA detection method was 79.4%. Conclusion Results of this work become further evident to state that if the focused stimulus (FS) will be able to elicit distinguishable VEP pattern regardless the non-focused stimulus (NFS) is also present.
  • Ngôn ngữ: Portuguese
  • Số nhận dạng: ISSN: 2446-4740 ; E-ISSN: 2446-4740 ; DOI: 10.1590/2446-4740.0752

Đang tìm Cơ sở dữ liệu bên ngoài...