skip to main content
Ngôn ngữ:
Giới hạn tìm kiếm: Giới hạn tìm kiếm: Dạng tài nguyên Hiển thị kết quả với: Hiển thị kết quả với: Chỉ mục

Assessment of the recycling potential of fresh concrete waste using a factorial design of experiments

Correia, S L ; Souza, F L ; Dienstmann, G ; Segadães, A M

Waste management (New York, N.Y.), November 2009, Vol.29(11), pp.2886-91 [Tạp chí có phản biện]

E-ISSN: 1879-2456 ; PMID: 19596189 Version:1 ; DOI: 10.1016/j.wasman.2009.06.014

Toàn văn sẵn có

Trích dẫn Trích dẫn bởi
  • Nhan đề:
    Assessment of the recycling potential of fresh concrete waste using a factorial design of experiments
  • Tác giả: Correia, S L ; Souza, F L ; Dienstmann, G ; Segadães, A M
  • Chủ đề: Construction Materials -- Analysis ; Industrial Waste -- Analysis ; Waste Management -- Methods
  • Là 1 phần của: Waste management (New York, N.Y.), November 2009, Vol.29(11), pp.2886-91
  • Mô tả: Recycling of industrial wastes and by-products can help reduce the cost of waste treatment prior to disposal and eventually preserve natural resources and energy. To assess the recycling potential of a given waste, it is important to select a tool capable of giving clear indications either way, with the least time and work consumption, as is the case of modelling the system properties using the results obtained from statistical design of experiments. In this work, the aggregate reclaimed from the mud that results from washout and cleaning operations of fresh concrete mixer trucks (fresh concrete waste, FCW) was recycled into new concrete with various water/cement ratios, as replacement of natural fine aggregates. A 3(2) factorial design of experiments was used to model fresh concrete consistency index and hardened concrete water absorption and 7- and 28-day compressive strength, as functions of FCW content and water/cement ratio, and the resulting regression equations and contour plots were validated with confirmation experiments. The results showed that the fresh concrete workability worsened with the increase in FCW content but the water absorption (5-10 wt.%), 7-day compressive strength (26-36 MPa) and 28-day compressive strength (32-44 MPa) remained within the specified ranges, thus demonstrating that the aggregate reclaimed from FCW can be recycled into new concrete mixtures with lower natural aggregate content.
  • Ngôn ngữ: English
  • Số nhận dạng: E-ISSN: 1879-2456 ; PMID: 19596189 Version:1 ; DOI: 10.1016/j.wasman.2009.06.014

Đang tìm Cơ sở dữ liệu bên ngoài...